PT - JOURNAL ARTICLE AU - Vinall, Maria ED - Bochard-Villanueva, Bruno TI - RT3D TEE Superior to 2D TEE in the Diagnosis and Treatment of Mitral Periprosthetic Leaks DP - 2014 01 TA - MD Conference Express PG - 9--11 VI - 14 IP - 54 4099 - http://mdc.sagepub.com/content/14/54/9.1.short 4100 - http://mdc.sagepub.com/content/14/54/9.1.full AB - This study compared 2-dimensional vs real-time 3-dimensional transesophageal echocardiography in the diagnosis and treatment of patients with mitral periprosthetic leaks. Benefits of real-time 3-dimensional transesophageal echocardiography include the accuracy and reliability with which it records measurements of chamber size and function, and its improved ability to delineate valvular and congenital abnormalities.