PT - JOURNAL ARTICLE AU - Parry, Nicola ED - von Birgelen, Clemens TI - Third-Generation ZES Matches EES in Efficacy and Safety, without Evidence of Longitudinal Deformation in an All-Comer Population DP - 2013 01 TA - MD Conference Express PG - 22--23 VI - 13 IP - 19 4099 - http://mdc.sagepub.com/content/13/19/22.short 4100 - http://mdc.sagepub.com/content/13/19/22.full AB - This article presents 1-year data from the Durable Polymer-Based Stent Challenge of Promus Element Versus Resolute Integrity in an All Comers Population [DUTCH PEERS (TWENTE II); von Birgelen C et al. Lancet 2013 (epublished ahead of print)] study. The results demonstrated comparable clinical outcomes with zotarolimus-eluting stents and everolimus-eluting stents (EES); both are third-generation, permanent, polymer-based, drug-eluting stents. There was no significant difference in efficacy and safety between the two stents, and longitudinal stent deformation was only seen in the EES group.