{"markup":"\u003C?xml version=\u00221.0\u0022 encoding=\u0022UTF-8\u0022 ?\u003E\n    \u003Chtml version=\u0022HTML+RDFa+MathML 1.1\u0022\n    xmlns:content=\u0022http:\/\/purl.org\/rss\/1.0\/modules\/content\/\u0022\n    xmlns:dc=\u0022http:\/\/purl.org\/dc\/terms\/\u0022\n    xmlns:foaf=\u0022http:\/\/xmlns.com\/foaf\/0.1\/\u0022\n    xmlns:og=\u0022http:\/\/ogp.me\/ns#\u0022\n    xmlns:rdfs=\u0022http:\/\/www.w3.org\/2000\/01\/rdf-schema#\u0022\n    xmlns:sioc=\u0022http:\/\/rdfs.org\/sioc\/ns#\u0022\n    xmlns:sioct=\u0022http:\/\/rdfs.org\/sioc\/types#\u0022\n    xmlns:skos=\u0022http:\/\/www.w3.org\/2004\/02\/skos\/core#\u0022\n    xmlns:xsd=\u0022http:\/\/www.w3.org\/2001\/XMLSchema#\u0022\n    xmlns:mml=\u0022http:\/\/www.w3.org\/1998\/Math\/MathML\u0022\u003E\n  \u003Chead\u003E\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/sites\/default\/files\/js\/js_itu2PgFdrjV-docKmLK8Jn5oXe_05RgvQh73eOhI_mE.js\u0022\u003E\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/mdc.sagepub.com\/sites\/all\/modules\/highwire\/highwire\/plugins\/highwire_markup_process\/js\/highwire_at_symbol.js?nzn721\u0022\u003E\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/mdc.sagepub.com\/sites\/all\/modules\/highwire\/highwire\/plugins\/highwire_markup_process\/js\/highwire_article_reference_popup.js?nzn721\u0022\u003E\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/sites\/default\/files\/js\/js_I8yX6RYPZb7AtMcDUA3QKDZqVkvEn35ED11_1i7vVpc.js\u0022\u003E\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022\u003E\n\u003C!--\/\/--\u003E\u003C![CDATA[\/\/\u003E\u003C!--\n(function(i,s,o,g,r,a,m){i[\u0022GoogleAnalyticsObject\u0022]=r;i[r]=i[r]||function(){(i[r].q=i[r].q||[]).push(arguments)},i[r].l=1*new Date();a=s.createElement(o),m=s.getElementsByTagName(o)[0];a.async=1;a.src=g;m.parentNode.insertBefore(a,m)})(window,document,\u0022script\u0022,\u0022\/\/www.google-analytics.com\/analytics.js\u0022,\u0022ga\u0022);ga(\u0022create\u0022, \u0022UA-15605596-27\u0022, {\u0022cookieDomain\u0022:\u0022auto\u0022});ga(\u0022set\u0022, \u0022page\u0022, location.pathname + location.search + location.hash);ga(\u0022send\u0022, \u0022pageview\u0022);ga(\u0027create\u0027, \u0027UA-189672-26\u0027, \u0027auto\u0027, {\u0027name\u0027: \u0027hwTracker\u0027});\r\nga(\u0027hwTracker.send\u0027, \u0027pageview\u0027);\n\/\/--\u003E\u003C!]]\u003E\n\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022\u003E\n\u003C!--\/\/--\u003E\u003C![CDATA[\/\/\u003E\u003C!--\njQuery.extend(Drupal.settings, {\u0022basePath\u0022:\u0022\\\/\u0022,\u0022pathPrefix\u0022:\u0022\u0022,\u0022highwire\u0022:{\u0022markup\u0022:[{\u0022requested\u0022:\u0022full-text\u0022,\u0022variant\u0022:\u0022full-text\u0022,\u0022view\u0022:\u0022full\u0022,\u0022pisa\u0022:\u0022spmdc;12\\\/17\\\/16\u0022},{\u0022requested\u0022:\u0022long\u0022,\u0022variant\u0022:\u0022full-text\u0022,\u0022view\u0022:\u0022full\u0022,\u0022pisa\u0022:\u0022spmdc;12\\\/17\\\/16\u0022}],\u0022ac\u0022:{\u0022spmdc;12\\\/17\\\/16\u0022:{\u0022access\u0022:{\u0022reprint\u0022:true,\u0022full\u0022:true},\u0022pisa_id\u0022:\u0022spmdc;12\\\/17\\\/16\u0022,\u0022atom_uri\u0022:\u0022\u0022,\u0022jcode\u0022:\u0022spmdc\u0022}}},\u0022googleanalytics\u0022:{\u0022trackOutbound\u0022:1,\u0022trackMailto\u0022:1,\u0022trackDownload\u0022:1,\u0022trackDownloadExtensions\u0022:\u00227z|aac|arc|arj|asf|asx|avi|bin|csv|doc(x|m)?|dot(x|m)?|exe|flv|gif|gz|gzip|hqx|jar|jpe?g|js|mp(2|3|4|e?g)|mov(ie)?|msi|msp|pdf|phps|png|ppt(x|m)?|pot(x|m)?|pps(x|m)?|ppam|sld(x|m)?|thmx|qtm?|ra(m|r)?|sea|sit|tar|tgz|torrent|txt|wav|wma|wmv|wpd|xls(x|m|b)?|xlt(x|m)|xlam|xml|z|zip\u0022,\u0022trackUrlFragments\u0022:1},\u0022ajaxPageState\u0022:{\u0022js\u0022:{\u0022sites\\\/all\\\/libraries\\\/cluetip\\\/jquery.cluetip.js\u0022:1,\u0022sites\\\/all\\\/libraries\\\/cluetip\\\/lib\\\/jquery.hoverIntent.js\u0022:1,\u0022sites\\\/all\\\/libraries\\\/cluetip\\\/lib\\\/jquery.bgiframe.min.js\u0022:1,\u0022sites\\\/all\\\/modules\\\/highwire\\\/highwire\\\/plugins\\\/highwire_markup_process\\\/js\\\/highwire_at_symbol.js\u0022:1,\u0022sites\\\/all\\\/modules\\\/highwire\\\/highwire\\\/plugins\\\/highwire_markup_process\\\/js\\\/highwire_article_reference_popup.js\u0022:1,\u0022sites\\\/all\\\/modules\\\/contrib\\\/google_analytics\\\/googleanalytics.js\u0022:1,\u00220\u0022:1}}});\n\/\/--\u003E\u003C!]]\u003E\n\u003C\/script\u003E\n\u003Clink type=\u0022text\/css\u0022 rel=\u0022stylesheet\u0022 href=\u0022\/\/d282kpwvnogo5m.cloudfront.net\/sites\/default\/files\/advagg_css\/css__ce2QY63WIanKyr8eSq7eavr1XQRRmFD6ZSmwpyJi8lM__zXwFqpqmxrZOXXcd_TpBQpjuELbmIP9wBR5UuTDWAO4__YJWWMMdfCJuAFm5cUEp88OsodhO3ZA-2lzRfoBsSlk4.css\u0022 media=\u0022all\u0022 \/\u003E\n\u003Clink rel=\u0027stylesheet\u0027 type=\u0027text\/css\u0027 href=\u0027\/sites\/all\/modules\/contrib\/panels\/plugins\/layouts\/onecol\/onecol.css\u0027 \/\u003E\u003C\/head\u003E\u003Cbody\u003E\u003Cdiv class=\u0022panels-ajax-tab-panel panels-ajax-tab-panel-sageoa-tab-art\u0022\u003E\u003Cdiv class=\u0022panel-display panel-1col clearfix\u0022 \u003E\n  \u003Cdiv class=\u0022panel-panel panel-col\u0022\u003E\n    \u003Cdiv\u003E\u003Cdiv class=\u0022panel-pane pane-highwire-markup\u0022 \u003E\n  \n      \n  \n  \u003Cdiv class=\u0022pane-content\u0022\u003E\n    \u003Cdiv class=\u0022highwire-markup\u0022\u003E\u003Cdiv xmlns=\u0022http:\/\/www.w3.org\/1999\/xhtml\u0022 id=\u0022content-block-markup\u0022 xmlns:xhtml=\u0022http:\/\/www.w3.org\/1999\/xhtml\u0022\u003E\u003Cdiv class=\u0022article fulltext-view \u0022\u003E\u003Cspan class=\u0022highwire-journal-article-marker-start\u0022\u003E\u003C\/span\u003E\u003Cdiv class=\u0022section abstract\u0022 id=\u0022abstract-1\u0022\u003E\u003Ch2\u003ESummary\u003C\/h2\u003E\n            \u003Cp id=\u0022p-1\u0022\u003EA novel, thin-strut, metal stent with a mesh covering significantly improved the achievement of complete ST-segment resolution compared with standard stents after percutaneous coronary intervention in patients with acute ST-segment elevation myocardial infarction. This article reports the findings of the Safety and Efficacy Study of MGuard Stent after a Heart Attack [MASTER] trial.\u003C\/p\u003E\n         \u003C\/div\u003E\u003Cul class=\u0022kwd-group\u0022\u003E\u003Cli class=\u0022kwd\u0022\u003EInterventional Techniques \u0026amp; Devices\u003C\/li\u003E\u003Cli class=\u0022kwd\u0022\u003ECardiology Clinical Trials\u003C\/li\u003E\u003Cli class=\u0022kwd\u0022\u003EMyocardial Infarction\u003C\/li\u003E\u003C\/ul\u003E\u003Cp id=\u0022p-2\u0022\u003EA novel, thin-strut, metal stent with a mesh covering significantly improved the achievement of complete ST-segment resolution (STR) compared with standard stents after percutaneous coronary intervention (PCI) in patients with acute ST-segment elevation myocardial infarction (STEMI). Gregg W. Stone, MD, Cardiovascular Research Foundation, New York, New York, USA, reported the findings of the Safety and Efficacy Study of MGuard Stent after a Heart Attack [MASTER] trial, which were also published simultaneously in the \u003Cem\u003EJournal of the American College of Cardiology\u003C\/em\u003E [Stone GW et al. 2012].\u003C\/p\u003E\u003Cp id=\u0022p-3\u0022\u003EDr. Stone described the stent used in the study as an embolic protection stent. The MGuard\u2122 stent has a polyethylene terephthalate micronet sleeve covering that is designed to trap thrombi and friable atheromatous debris, thereby preventing distal embolization during PCI. PCI-induced distal embolization is thought to contribute to suboptimal myocardial perfusion after PCI, which is common and results in increased infarct size and mortality.\u003C\/p\u003E\u003Cp id=\u0022p-4\u0022\u003EThe MASTER trial enrolled 433 patients at 50 sites in 9 countries. All patients had acute STEMI, were seen within 12 hours of symptom onset, and were treated with emergent PCI. The patients were randomly assigned to treatment with the mesh-covered MGuard stent (n=217) or with a commercially available bare-metal or drug-eluting stent (n=216). The primary endpoint was the rate of complete STR, defined as a \u226570% reduction in the summed 12-lead extent of ST-segment elevation from the baseline electrocardiogram (ECG) to ECG done 60 to 90 minutes after PCI. Dr. Stone said complete STR is a strong surrogate for subsequent survival.\u003C\/p\u003E\u003Cp id=\u0022p-5\u0022\u003EThe trial met its endpoint with a significantly higher rate of complete STR for the MGuard stent compared with the standard stents (57.8% vs 44.7%; p=0.008; \u003Ca id=\u0022xref-fig-1-1\u0022 class=\u0022xref-fig\u0022 href=\u0022#F1\u0022\u003EFigure 1\u003C\/a\u003E). The MGuard stent was also associated with a significantly higher rate of TIMI-3 epicardial coronary flow compared with the standard stents (91.7% vs 82.9%; p=0.006). The rates of grade 2 or 3 myocardial blush were similar for the 2 groups (83.9% vs 84.7%; p=0.81).\u003C\/p\u003E\u003Cdiv id=\u0022F1\u0022 class=\u0022fig pos-float  odd\u0022\u003E\u003Cdiv class=\u0022highwire-figure\u0022\u003E\u003Cdiv class=\u0022fig-inline-img-wrapper\u0022\u003E\u003Cdiv class=\u0022fig-inline-img\u0022\u003E\u003Ca href=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/content\/spmdc\/12\/17\/16\/F1.large.jpg?width=800\u0026amp;height=600\u0026amp;carousel=1\u0022 title=\u0022Primary Endpoint: Complete ST-Segment Resolution.\u0022 class=\u0022fragment-images colorbox-load\u0022 rel=\u0022gallery-fragment-images-508919475\u0022 data-figure-caption=\u0022Primary Endpoint: Complete ST-Segment Resolution.\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003E\u003Cimg class=\u0022fragment-image\u0022 alt=\u0022Figure 1.\u0022 src=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/content\/spmdc\/12\/17\/16\/F1.medium.gif\u0022\/\u003E\u003C\/a\u003E\u003C\/div\u003E\u003C\/div\u003E\u003Cul class=\u0022highwire-figure-links inline\u0022\u003E\u003Cli class=\u00220 first\u0022\u003E\u003Ca href=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/content\/spmdc\/12\/17\/16\/F1.large.jpg?download=true\u0022 class=\u0022highwire-figure-link highwire-figure-link-download\u0022 title=\u0022Download Figure 1.\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003EDownload figure\u003C\/a\u003E\u003C\/li\u003E\u003Cli class=\u00221\u0022\u003E\u003Ca href=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/content\/spmdc\/12\/17\/16\/F1.large.jpg\u0022 class=\u0022highwire-figure-link highwire-figure-link-newtab\u0022 target=\u0022_blank\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003EOpen in new tab\u003C\/a\u003E\u003C\/li\u003E\u003Cli class=\u00222 last\u0022\u003E\u003Ca href=\u0022\/highwire\/powerpoint\/14265\u0022 class=\u0022highwire-figure-link highwire-figure-link-ppt\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003EDownload powerpoint\u003C\/a\u003E\u003C\/li\u003E\u003C\/ul\u003E\u003C\/div\u003E\u003Cdiv class=\u0022fig-caption attrib\u0022\u003E\u003Cspan class=\u0022fig-label\u0022\u003EFigure 1.\u003C\/span\u003E \n            \u003Cp id=\u0022p-6\u0022 class=\u0022first-child\u0022\u003EPrimary Endpoint: Complete ST-Segment Resolution.\u003C\/p\u003E\n         \u003Cq class=\u0022attrib\u0022 id=\u0022attrib-1\u0022\u003EReproduced with permission from GW Stone, MD.\u003C\/q\u003E\u003Cdiv class=\u0022sb-div caption-clear\u0022\u003E\u003C\/div\u003E\u003C\/div\u003E\u003C\/div\u003E\u003Cp id=\u0022p-7\u0022\u003EDr. Stone reported clinical events at 30 days and acknowledged that the trial was underpowered for these events. The rate of major adverse cardiovascular events was similar for the MGuard stent and standard stent(1.8% vs 2.3%; p=0.75). Similarly, no significant difference in mortality was observed between the MGuard group (n=0) versus the standard group (n=4; p=0.06), but mortality trended in favor of the MGuard consistent with the STR findings.\u003C\/p\u003E\u003Cp id=\u0022p-8\u0022\u003ELong-term clinical and angiographic follow-up of the patients in the trial is ongoing. A larger randomized trial is needed to determine whether the use of an embolic protection stent results in reduced infarct size and improved clinical outcomes.\u003C\/p\u003E\u003Cul class=\u0022copyright-statement\u0022\u003E\u003Cli class=\u0022fn\u0022 id=\u0022copyright-statement-1\u0022\u003E\u00a9 2012 MD Conference Express\u00ae\u003C\/li\u003E\u003C\/ul\u003E\u003Cspan class=\u0022highwire-journal-article-marker-end\u0022\u003E\u003C\/span\u003E\u003C\/div\u003E\u003Cspan id=\u0022related-urls\u0022\u003E\u003C\/span\u003E\u003C\/div\u003E\u003Ca href=\u0022http:\/\/mdc.sagepub.com\/content\/12\/17\/16.abstract\u0022 class=\u0022hw-link hw-link-article-abstract\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003EView Summary\u003C\/a\u003E\u003C\/div\u003E  \u003C\/div\u003E\n\n  \n  \u003C\/div\u003E\n\u003C\/div\u003E\n  \u003C\/div\u003E\n\u003C\/div\u003E\n\u003C\/div\u003E\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/mdc.sagepub.com\/sites\/all\/modules\/highwire\/highwire\/plugins\/highwire_markup_process\/js\/highwire_figures.js?nzn721\u0022\u003E\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/mdc.sagepub.com\/sites\/all\/modules\/highwire\/highwire\/plugins\/highwire_markup_process\/js\/highwire_openurl.js?nzn721\u0022\u003E\u003C\/script\u003E\n\u003C\/body\u003E\u003C\/html\u003E"}