Day and Night Closed-Loop Glucose Control is Feasible in Type 1 Diabetes

Summary

Twenty-four-hour glucose control using a closed-loop system was feasible and resulted in improved glucose control without increasing hypoglycemic events, according to data from the Closing the Loop in Adults With Sub-optimally Controlled Type 1 Diabetes Under Free Living Conditions study [AP@home02; NCT01666028]. The purpose of the AP@home02 study was to determine the feasibility of using a closed-loop insulin delivery system, combining an insulin pump and continuous glucose monitoring, for glucose control for 7 days in patients with type 1 diabetes mellitus.

  • Diabetes Mellitus
  • Hyperglycemia/Hypoglycemia
  • Diabetes & Endocrinology Clinical Trials
  • Diabetes Mellitus
  • Hyperglycemia/Hypoglycemia
  • Diabetes & Endocrinology Clinical Trials
  • Endocrinology
  • Diabetes & Metabolic Syndrome
View Full Text