{"markup":"\u003C?xml version=\u00221.0\u0022 encoding=\u0022UTF-8\u0022 ?\u003E\n    \u003Chtml version=\u0022HTML+RDFa+MathML 1.1\u0022\n    xmlns:content=\u0022http:\/\/purl.org\/rss\/1.0\/modules\/content\/\u0022\n    xmlns:dc=\u0022http:\/\/purl.org\/dc\/terms\/\u0022\n    xmlns:foaf=\u0022http:\/\/xmlns.com\/foaf\/0.1\/\u0022\n    xmlns:og=\u0022http:\/\/ogp.me\/ns#\u0022\n    xmlns:rdfs=\u0022http:\/\/www.w3.org\/2000\/01\/rdf-schema#\u0022\n    xmlns:sioc=\u0022http:\/\/rdfs.org\/sioc\/ns#\u0022\n    xmlns:sioct=\u0022http:\/\/rdfs.org\/sioc\/types#\u0022\n    xmlns:skos=\u0022http:\/\/www.w3.org\/2004\/02\/skos\/core#\u0022\n    xmlns:xsd=\u0022http:\/\/www.w3.org\/2001\/XMLSchema#\u0022\n    xmlns:mml=\u0022http:\/\/www.w3.org\/1998\/Math\/MathML\u0022\u003E\n  \u003Chead\u003E\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/sites\/default\/files\/js\/js_itu2PgFdrjV-docKmLK8Jn5oXe_05RgvQh73eOhI_mE.js\u0022\u003E\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/mdc.sagepub.com\/sites\/all\/modules\/highwire\/highwire\/plugins\/highwire_markup_process\/js\/highwire_at_symbol.js?nzndl1\u0022\u003E\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/mdc.sagepub.com\/sites\/all\/modules\/highwire\/highwire\/plugins\/highwire_markup_process\/js\/highwire_article_reference_popup.js?nzndl1\u0022\u003E\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/sites\/default\/files\/js\/js_I8yX6RYPZb7AtMcDUA3QKDZqVkvEn35ED11_1i7vVpc.js\u0022\u003E\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022\u003E\n\u003C!--\/\/--\u003E\u003C![CDATA[\/\/\u003E\u003C!--\n(function(i,s,o,g,r,a,m){i[\u0022GoogleAnalyticsObject\u0022]=r;i[r]=i[r]||function(){(i[r].q=i[r].q||[]).push(arguments)},i[r].l=1*new Date();a=s.createElement(o),m=s.getElementsByTagName(o)[0];a.async=1;a.src=g;m.parentNode.insertBefore(a,m)})(window,document,\u0022script\u0022,\u0022\/\/www.google-analytics.com\/analytics.js\u0022,\u0022ga\u0022);ga(\u0022create\u0022, \u0022UA-15605596-27\u0022, {\u0022cookieDomain\u0022:\u0022auto\u0022});ga(\u0022set\u0022, \u0022page\u0022, location.pathname + location.search + location.hash);ga(\u0022send\u0022, \u0022pageview\u0022);ga(\u0027create\u0027, \u0027UA-189672-26\u0027, \u0027auto\u0027, {\u0027name\u0027: \u0027hwTracker\u0027});\r\nga(\u0027hwTracker.send\u0027, \u0027pageview\u0027);\n\/\/--\u003E\u003C!]]\u003E\n\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022\u003E\n\u003C!--\/\/--\u003E\u003C![CDATA[\/\/\u003E\u003C!--\njQuery.extend(Drupal.settings, {\u0022basePath\u0022:\u0022\\\/\u0022,\u0022pathPrefix\u0022:\u0022\u0022,\u0022highwire\u0022:{\u0022markup\u0022:[{\u0022requested\u0022:\u0022full-text\u0022,\u0022variant\u0022:\u0022full-text\u0022,\u0022view\u0022:\u0022full\u0022,\u0022pisa\u0022:\u0022spmdc;12\\\/6\\\/10\u0022},{\u0022requested\u0022:\u0022long\u0022,\u0022variant\u0022:\u0022full-text\u0022,\u0022view\u0022:\u0022full\u0022,\u0022pisa\u0022:\u0022spmdc;12\\\/6\\\/10\u0022}],\u0022ac\u0022:{\u0022spmdc;12\\\/6\\\/10\u0022:{\u0022access\u0022:{\u0022reprint\u0022:true,\u0022full\u0022:true},\u0022pisa_id\u0022:\u0022spmdc;12\\\/6\\\/10\u0022,\u0022atom_uri\u0022:\u0022\u0022,\u0022jcode\u0022:\u0022spmdc\u0022}}},\u0022googleanalytics\u0022:{\u0022trackOutbound\u0022:1,\u0022trackMailto\u0022:1,\u0022trackDownload\u0022:1,\u0022trackDownloadExtensions\u0022:\u00227z|aac|arc|arj|asf|asx|avi|bin|csv|doc(x|m)?|dot(x|m)?|exe|flv|gif|gz|gzip|hqx|jar|jpe?g|js|mp(2|3|4|e?g)|mov(ie)?|msi|msp|pdf|phps|png|ppt(x|m)?|pot(x|m)?|pps(x|m)?|ppam|sld(x|m)?|thmx|qtm?|ra(m|r)?|sea|sit|tar|tgz|torrent|txt|wav|wma|wmv|wpd|xls(x|m|b)?|xlt(x|m)|xlam|xml|z|zip\u0022,\u0022trackUrlFragments\u0022:1},\u0022ajaxPageState\u0022:{\u0022js\u0022:{\u0022sites\\\/all\\\/libraries\\\/cluetip\\\/jquery.cluetip.js\u0022:1,\u0022sites\\\/all\\\/libraries\\\/cluetip\\\/lib\\\/jquery.hoverIntent.js\u0022:1,\u0022sites\\\/all\\\/libraries\\\/cluetip\\\/lib\\\/jquery.bgiframe.min.js\u0022:1,\u0022sites\\\/all\\\/modules\\\/highwire\\\/highwire\\\/plugins\\\/highwire_markup_process\\\/js\\\/highwire_at_symbol.js\u0022:1,\u0022sites\\\/all\\\/modules\\\/highwire\\\/highwire\\\/plugins\\\/highwire_markup_process\\\/js\\\/highwire_article_reference_popup.js\u0022:1,\u0022sites\\\/all\\\/modules\\\/contrib\\\/google_analytics\\\/googleanalytics.js\u0022:1,\u00220\u0022:1}}});\n\/\/--\u003E\u003C!]]\u003E\n\u003C\/script\u003E\n\u003Clink type=\u0022text\/css\u0022 rel=\u0022stylesheet\u0022 href=\u0022\/\/d282kpwvnogo5m.cloudfront.net\/sites\/default\/files\/advagg_css\/css__ce2QY63WIanKyr8eSq7eavr1XQRRmFD6ZSmwpyJi8lM__zXwFqpqmxrZOXXcd_TpBQpjuELbmIP9wBR5UuTDWAO4__YJWWMMdfCJuAFm5cUEp88OsodhO3ZA-2lzRfoBsSlk4.css\u0022 media=\u0022all\u0022 \/\u003E\n\u003Clink rel=\u0027stylesheet\u0027 type=\u0027text\/css\u0027 href=\u0027\/sites\/all\/modules\/contrib\/panels\/plugins\/layouts\/onecol\/onecol.css\u0027 \/\u003E\u003C\/head\u003E\u003Cbody\u003E\u003Cdiv class=\u0022panels-ajax-tab-panel panels-ajax-tab-panel-sageoa-tab-art\u0022\u003E\u003Cdiv class=\u0022panel-display panel-1col clearfix\u0022 \u003E\n  \u003Cdiv class=\u0022panel-panel panel-col\u0022\u003E\n    \u003Cdiv\u003E\u003Cdiv class=\u0022panel-pane pane-highwire-markup\u0022 \u003E\n  \n      \n  \n  \u003Cdiv class=\u0022pane-content\u0022\u003E\n    \u003Cdiv class=\u0022highwire-markup\u0022\u003E\u003Cdiv xmlns=\u0022http:\/\/www.w3.org\/1999\/xhtml\u0022 id=\u0022content-block-markup\u0022 xmlns:xhtml=\u0022http:\/\/www.w3.org\/1999\/xhtml\u0022\u003E\u003Cdiv class=\u0022article fulltext-view \u0022\u003E\u003Cspan class=\u0022highwire-journal-article-marker-start\u0022\u003E\u003C\/span\u003E\u003Cdiv class=\u0022section abstract\u0022 id=\u0022abstract-1\u0022\u003E\u003Ch2\u003ESummary\u003C\/h2\u003E\n            \u003Cp id=\u0022p-1\u0022\u003EAn investigational, fully subcutaneous implantable cardioverter defibrillator (S-ICD) that senses, detects, and treats malignant ventricular tachyarrhythmias exceeded prespecified safety and efficacy endpoints in a recent clinical trial, potentially paving the way for a paradigm shift in ICD technology.\u003C\/p\u003E\n         \u003C\/div\u003E\u003Cp id=\u0022p-2\u0022\u003EAn investigational, fully subcutaneous implantable cardioverter defibrillator (S-ICD) that senses, detects, and treats malignant ventricular tachyarrhythmias exceeded prespecified safety and efficacy endpoints in a recent clinical trial, potentially paving the way for a paradigm shift in ICD technology. Martin C. Burke, DO, University of Chicago, Chicago, Illinois, USA, reported findings from this study.\u003C\/p\u003E\u003Cp id=\u0022p-3\u0022\u003EInvestigators enrolled 330 patients at 33 centers in the United States, New Zealand, the Netherlands, and the United Kingdom to perform a prospective, single-arm comparison of the S-ICD to objective performance criteria. Patients were aged \u226518 years, met guidelines for ICD implantation or replacement of an existing ICD system, and had appropriate preoperative electrocardiograms. The S-ICD system was used for primary prevention in 79% of the patients. Characteristics of the population are shown in \u003Ca id=\u0022xref-table-wrap-1-1\u0022 class=\u0022xref-table\u0022 href=\u0022#T1\u0022\u003ETable 1\u003C\/a\u003E.\u003C\/p\u003E\u003Cdiv id=\u0022T1\u0022 class=\u0022table pos-float\u0022\u003E\u003Cdiv class=\u0022table-inline\u0022\u003E\u003Cdiv class=\u0022callout\u0022\u003E\u003Cspan\u003EView this table:\u003C\/span\u003E\u003Cul class=\u0022callout-links\u0022\u003E\u003Cli class=\u00220 first\u0022\u003E\u003Ca href=\u0022\/\u0022 class=\u0022table-expand-inline\u0022 data-table-url=\u0022\/highwire\/markup\/14379\/expansion?postprocessors=highwire_figures%2Chighwire_math%2Chighwire_inline_linked_media%2Chighwire_embed\u0026amp;table-expand-inline=1\u0022 html=\u00221\u0022 fragment=\u0022#\u0022 external=\u00221\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003EView inline\u003C\/a\u003E\u003C\/li\u003E\u003Cli class=\u00221\u0022\u003E\u003Ca href=\u0022\/highwire\/markup\/14379\/expansion?width=1000\u0026amp;height=500\u0026amp;iframe=true\u0026amp;postprocessors=highwire_figures%2Chighwire_math%2Chighwire_inline_linked_media\u0022 class=\u0022colorbox colorbox-load table-expand-popup\u0022 rel=\u0022gallery-fragment-tables\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003EView popup\u003C\/a\u003E\u003C\/li\u003E\u003Cli class=\u00222 last\u0022\u003E\u003Ca href=\u0022\/highwire\/powerpoint\/14379\u0022 class=\u0022highwire-figure-link highwire-figure-link-ppt\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003EDownload powerpoint\u003C\/a\u003E\u003C\/li\u003E\u003C\/ul\u003E\u003C\/div\u003E\u003C\/div\u003E\u003Cdiv class=\u0022table-caption\u0022\u003E\u003Cspan class=\u0022table-label\u0022\u003ETable 1.\u003C\/span\u003E \n            \u003Cp id=\u0022p-4\u0022 class=\u0022first-child\u0022\u003EBaseline Characteristics of S-ICD Subjects.\u003C\/p\u003E\n         \u003Cdiv class=\u0022sb-div caption-clear\u0022\u003E\u003C\/div\u003E\u003C\/div\u003E\u003C\/div\u003E\u003Cp id=\u0022p-6\u0022\u003EDevices were implanted in 321 patients; only anatomical landmarks were used in 95% of patients. During the follow-up period, no electrode or pulse generator movement was detected in 99% of patients. Of 18 (5.6%) suspected or confirmed infections, 14 (4.4%) were superficial or incisional and were managed without explantation. The 4 that required explantation occurred early in the study.\u003C\/p\u003E\u003Cp id=\u0022p-7\u0022\u003EThe primary efficacy endpoint was an acute ventricular fibrillation (VF) conversion rate that was greater than 88%. The S-ICD system successfully converted 100% of investigator-induced VFs, surpassing the prespecified target. The primary safety endpoint was the complication-free rate at 180 days, with a prespecified goal of at least 79%. In the study, the 180-day Type 1 complication-free rate was 99%.\u003C\/p\u003E\u003Cp id=\u0022p-8\u0022\u003EThe 180-day performance goal of freedom from all device-, labeling-, and procedure-related complications was 79%; the observed rate in the study was 92.1%. All spontaneous episodes were successfully converted with 80J or spontaneously converted, and unnecessary therapy was avoided. No patients experienced a shock because of discrimination error in the conditional shock (dual) zone, and the rate of inappropriate shocks was similar to that of standard transvenous devices.\u003C\/p\u003E\u003Cp id=\u0022p-9\u0022\u003EAccording to Dr. Burke, the S-ICD system exceeded all objective performance criteria for safety and efficacy.\u003C\/p\u003E\u003Cul class=\u0022copyright-statement\u0022\u003E\u003Cli class=\u0022fn\u0022 id=\u0022copyright-statement-1\u0022\u003E\u00a9 2012 MD Conference Express\u003C\/li\u003E\u003C\/ul\u003E\u003Cspan class=\u0022highwire-journal-article-marker-end\u0022\u003E\u003C\/span\u003E\u003C\/div\u003E\u003Cspan id=\u0022related-urls\u0022\u003E\u003C\/span\u003E\u003C\/div\u003E\u003Ca href=\u0022http:\/\/mdc.sagepub.com\/content\/12\/6\/10.abstract\u0022 class=\u0022hw-link hw-link-article-abstract\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003EView Summary\u003C\/a\u003E\u003C\/div\u003E  \u003C\/div\u003E\n\n  \n  \u003C\/div\u003E\n\u003C\/div\u003E\n  \u003C\/div\u003E\n\u003C\/div\u003E\n\u003C\/div\u003E\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/mdc.sagepub.com\/sites\/all\/modules\/highwire\/highwire\/plugins\/highwire_markup_process\/js\/highwire_openurl.js?nzndl1\u0022\u003E\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/mdc.sagepub.com\/sites\/all\/modules\/highwire\/highwire\/plugins\/highwire_markup_process\/js\/highwire_tables.js?nzndl1\u0022\u003E\u003C\/script\u003E\n\u003C\/body\u003E\u003C\/html\u003E"}