{"markup":"\u003C?xml version=\u00221.0\u0022 encoding=\u0022UTF-8\u0022 ?\u003E\n    \u003Chtml version=\u0022HTML+RDFa+MathML 1.1\u0022\n    xmlns:content=\u0022http:\/\/purl.org\/rss\/1.0\/modules\/content\/\u0022\n    xmlns:dc=\u0022http:\/\/purl.org\/dc\/terms\/\u0022\n    xmlns:foaf=\u0022http:\/\/xmlns.com\/foaf\/0.1\/\u0022\n    xmlns:og=\u0022http:\/\/ogp.me\/ns#\u0022\n    xmlns:rdfs=\u0022http:\/\/www.w3.org\/2000\/01\/rdf-schema#\u0022\n    xmlns:sioc=\u0022http:\/\/rdfs.org\/sioc\/ns#\u0022\n    xmlns:sioct=\u0022http:\/\/rdfs.org\/sioc\/types#\u0022\n    xmlns:skos=\u0022http:\/\/www.w3.org\/2004\/02\/skos\/core#\u0022\n    xmlns:xsd=\u0022http:\/\/www.w3.org\/2001\/XMLSchema#\u0022\n    xmlns:mml=\u0022http:\/\/www.w3.org\/1998\/Math\/MathML\u0022\u003E\n  \u003Chead\u003E\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/sites\/default\/files\/js\/js_itu2PgFdrjV-docKmLK8Jn5oXe_05RgvQh73eOhI_mE.js\u0022\u003E\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/mdc.sagepub.com\/sites\/all\/modules\/highwire\/highwire\/plugins\/highwire_markup_process\/js\/highwire_at_symbol.js?nzm92r\u0022\u003E\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/mdc.sagepub.com\/sites\/all\/modules\/highwire\/highwire\/plugins\/highwire_markup_process\/js\/highwire_article_reference_popup.js?nzm92r\u0022\u003E\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/sites\/default\/files\/js\/js_I8yX6RYPZb7AtMcDUA3QKDZqVkvEn35ED11_1i7vVpc.js\u0022\u003E\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022\u003E\n\u003C!--\/\/--\u003E\u003C![CDATA[\/\/\u003E\u003C!--\n(function(i,s,o,g,r,a,m){i[\u0022GoogleAnalyticsObject\u0022]=r;i[r]=i[r]||function(){(i[r].q=i[r].q||[]).push(arguments)},i[r].l=1*new Date();a=s.createElement(o),m=s.getElementsByTagName(o)[0];a.async=1;a.src=g;m.parentNode.insertBefore(a,m)})(window,document,\u0022script\u0022,\u0022\/\/www.google-analytics.com\/analytics.js\u0022,\u0022ga\u0022);ga(\u0022create\u0022, \u0022UA-15605596-27\u0022, {\u0022cookieDomain\u0022:\u0022auto\u0022});ga(\u0022set\u0022, \u0022page\u0022, location.pathname + location.search + location.hash);ga(\u0022send\u0022, \u0022pageview\u0022);ga(\u0027create\u0027, \u0027UA-189672-26\u0027, \u0027auto\u0027, {\u0027name\u0027: \u0027hwTracker\u0027});\r\nga(\u0027hwTracker.send\u0027, \u0027pageview\u0027);\n\/\/--\u003E\u003C!]]\u003E\n\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022\u003E\n\u003C!--\/\/--\u003E\u003C![CDATA[\/\/\u003E\u003C!--\njQuery.extend(Drupal.settings, {\u0022basePath\u0022:\u0022\\\/\u0022,\u0022pathPrefix\u0022:\u0022\u0022,\u0022highwire\u0022:{\u0022markup\u0022:[{\u0022requested\u0022:\u0022full-text\u0022,\u0022variant\u0022:\u0022full-text\u0022,\u0022view\u0022:\u0022full\u0022,\u0022pisa\u0022:\u0022spmdc;7\\\/5\\\/19\u0022},{\u0022requested\u0022:\u0022long\u0022,\u0022variant\u0022:\u0022full-text\u0022,\u0022view\u0022:\u0022full\u0022,\u0022pisa\u0022:\u0022spmdc;7\\\/5\\\/19\u0022}],\u0022ac\u0022:{\u0022spmdc;7\\\/5\\\/19\u0022:{\u0022access\u0022:{\u0022reprint\u0022:true,\u0022full\u0022:true},\u0022pisa_id\u0022:\u0022spmdc;7\\\/5\\\/19\u0022,\u0022atom_uri\u0022:\u0022\u0022,\u0022jcode\u0022:\u0022spmdc\u0022}}},\u0022googleanalytics\u0022:{\u0022trackOutbound\u0022:1,\u0022trackMailto\u0022:1,\u0022trackDownload\u0022:1,\u0022trackDownloadExtensions\u0022:\u00227z|aac|arc|arj|asf|asx|avi|bin|csv|doc(x|m)?|dot(x|m)?|exe|flv|gif|gz|gzip|hqx|jar|jpe?g|js|mp(2|3|4|e?g)|mov(ie)?|msi|msp|pdf|phps|png|ppt(x|m)?|pot(x|m)?|pps(x|m)?|ppam|sld(x|m)?|thmx|qtm?|ra(m|r)?|sea|sit|tar|tgz|torrent|txt|wav|wma|wmv|wpd|xls(x|m|b)?|xlt(x|m)|xlam|xml|z|zip\u0022,\u0022trackUrlFragments\u0022:1},\u0022ajaxPageState\u0022:{\u0022js\u0022:{\u0022sites\\\/all\\\/libraries\\\/cluetip\\\/jquery.cluetip.js\u0022:1,\u0022sites\\\/all\\\/libraries\\\/cluetip\\\/lib\\\/jquery.hoverIntent.js\u0022:1,\u0022sites\\\/all\\\/libraries\\\/cluetip\\\/lib\\\/jquery.bgiframe.min.js\u0022:1,\u0022sites\\\/all\\\/modules\\\/highwire\\\/highwire\\\/plugins\\\/highwire_markup_process\\\/js\\\/highwire_at_symbol.js\u0022:1,\u0022sites\\\/all\\\/modules\\\/highwire\\\/highwire\\\/plugins\\\/highwire_markup_process\\\/js\\\/highwire_article_reference_popup.js\u0022:1,\u0022sites\\\/all\\\/modules\\\/contrib\\\/google_analytics\\\/googleanalytics.js\u0022:1,\u00220\u0022:1}}});\n\/\/--\u003E\u003C!]]\u003E\n\u003C\/script\u003E\n\u003Clink type=\u0022text\/css\u0022 rel=\u0022stylesheet\u0022 href=\u0022\/\/d282kpwvnogo5m.cloudfront.net\/sites\/default\/files\/cdn\/css\/http\/css_Xg7z6oCTVgud_Q0huYz9x9iiD5H_2YPSJ5z2ZViSWdY.css\u0022 media=\u0022all\u0022 \/\u003E\n\u003Clink rel=\u0027stylesheet\u0027 type=\u0027text\/css\u0027 href=\u0027\/sites\/all\/modules\/contrib\/panels\/plugins\/layouts\/onecol\/onecol.css\u0027 \/\u003E\u003C\/head\u003E\u003Cbody\u003E\u003Cdiv class=\u0022panels-ajax-tab-panel panels-ajax-tab-panel-sageoa-tab-art\u0022\u003E\u003Cdiv class=\u0022panel-display panel-1col clearfix\u0022 \u003E\n  \u003Cdiv class=\u0022panel-panel panel-col\u0022\u003E\n    \u003Cdiv\u003E\u003Cdiv class=\u0022panel-pane pane-highwire-markup\u0022 \u003E\n  \n      \n  \n  \u003Cdiv class=\u0022pane-content\u0022\u003E\n    \u003Cdiv class=\u0022highwire-markup\u0022\u003E\u003Cdiv xmlns=\u0022http:\/\/www.w3.org\/1999\/xhtml\u0022 id=\u0022content-block-markup\u0022 xmlns:xhtml=\u0022http:\/\/www.w3.org\/1999\/xhtml\u0022\u003E\u003Cdiv class=\u0022article fulltext-view \u0022\u003E\u003Cspan class=\u0022highwire-journal-article-marker-start\u0022\u003E\u003C\/span\u003E\u003Cdiv class=\u0022section abstract\u0022 id=\u0022abstract-1\u0022\u003E\u003Ch2\u003ESummary\u003C\/h2\u003E\n            \u003Cp id=\u0022p-1\u0022\u003EThe gold standard for the diagnosis of coronary artery disease (CAD) has been conventional coronary angiography. However, multislice computed tomography (MSCT) has shown promise as a less invasive diagnostic modality. This article presents the results of a prospective management outcome study to evaluate the safety of ruling out CAD on the basis of normal findings on MSCT\u003C\/p\u003E\n         \u003C\/div\u003E\u003Cul class=\u0022kwd-group\u0022\u003E\u003Cli class=\u0022kwd\u0022\u003Ecardiac imaging techniques\u003C\/li\u003E\u003Cli class=\u0022kwd\u0022\u003Etomography\u003C\/li\u003E\u003Cli class=\u0022kwd\u0022\u003Eradiography\u003C\/li\u003E\u003Cli class=\u0022kwd\u0022\u003Ecoronary artery disease\u003C\/li\u003E\u003Cli class=\u0022kwd\u0022\u003Eimaging modalities\u003C\/li\u003E\u003C\/ul\u003E\u003Cdiv class=\u0022section\u0022 id=\u0022sec-1\u0022\u003E\n         \n         \u003Cdiv id=\u0022F1\u0022 class=\u0022fig pos-float  odd\u0022\u003E\u003Cdiv class=\u0022highwire-figure\u0022\u003E\u003Cdiv class=\u0022fig-inline-img-wrapper\u0022\u003E\u003Cdiv class=\u0022fig-inline-img\u0022\u003E\u003Ca href=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/content\/spmdc\/7\/5\/19\/F1.large.jpg?width=800\u0026amp;height=600\u0026amp;carousel=1\u0022 title=\u0022\u0022 class=\u0022fragment-images colorbox-load\u0022 rel=\u0022gallery-fragment-images-1809220223\u0022 data-figure-caption=\u0022\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003E\u003Cimg class=\u0022fragment-image\u0022 alt=\u0022Figure1\u0022 src=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/content\/spmdc\/7\/5\/19\/F1.medium.gif\u0022\/\u003E\u003C\/a\u003E\u003C\/div\u003E\u003C\/div\u003E\u003Cul class=\u0022highwire-figure-links inline\u0022\u003E\u003Cli class=\u00220 first\u0022\u003E\u003Ca href=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/content\/spmdc\/7\/5\/19\/F1.large.jpg?download=true\u0022 class=\u0022highwire-figure-link highwire-figure-link-download\u0022 title=\u0022Download Figure1\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003EDownload figure\u003C\/a\u003E\u003C\/li\u003E\u003Cli class=\u00221\u0022\u003E\u003Ca href=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/content\/spmdc\/7\/5\/19\/F1.large.jpg\u0022 class=\u0022highwire-figure-link highwire-figure-link-newtab\u0022 target=\u0022_blank\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003EOpen in new tab\u003C\/a\u003E\u003C\/li\u003E\u003Cli class=\u00222 last\u0022\u003E\u003Ca href=\u0022\/highwire\/powerpoint\/11214\u0022 class=\u0022highwire-figure-link highwire-figure-link-ppt\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003EDownload powerpoint\u003C\/a\u003E\u003C\/li\u003E\u003C\/ul\u003E\u003C\/div\u003E\u003C\/div\u003E\n         \u003Cp id=\u0022p-2\u0022\u003EThe gold standard for the diagnosis of coronary artery disease (CAD) has been conventional coronary angiography. However, multislice computed tomography (MSCT) has shown promise as a less invasive diagnostic modality. When compared with conventional angiography in patients with suspected CAD, MSCT (4-,16-, and 64-slice) has been associated with a sensitivity of 85\u201399%, a specificity of 95\u201397%, a positive predictive value of 76\u201397%, and a negative predictive value of 97% [Schuijf JD et al. \u003Cem\u003EAm Heart J\u003C\/em\u003E 2006]. In addition, the use of MSCT avoids the complications, discomfort, and expense associated with conventional angiography; 64-slice CT has the additional advantage of quick (13 second) imaging that reduces motion artifact and thus further improves accuracy. As such, MSCT has the potential to play an important role in ruling out CAD in a less invasive and more cost-effective manner.\u003C\/p\u003E\n         \u003Cp id=\u0022p-3\u0022\u003EMartine Gilard, MD, Brest University Hospital, Brest Cedex, France, presented the results of a prospective management outcome study to evaluate the safety of ruling out CAD on the basis of normal findings on MSCT. In this study, 200 patients scheduled for conventional coronary angiography were evaluated with MSCT; 141 patients with normal findings on MSCT were followed up for a mean of 14.7 months (range, 6\u201326 months). The outcomes for these patients were compared with those for patients with normal findings on coronary angiography.\u003C\/p\u003E\n         \u003Cp id=\u0022p-4\u0022\u003EProf. Gilard reported that there were no deaths, one myocardial infarction (0.7%), and five referrals for conventional angiography (3.5%). These results compare favorably with those reported in the literature with normal conventional angiography [Lichtlen PR et al. \u003Cem\u003EJ Am Coll Cardiol\u003C\/em\u003E 1995].\u003C\/p\u003E\n         \u003Cp id=\u0022p-5\u0022\u003EAmong the five subsequent angiographies, two demonstrated normal results and three showed evidence of significant lesions. Thus, 137 (97.2%) of the 141 patients was clinically event-free, leading Prof. Gilard and colleagues to conclude that for individuals with suspected significant CAD, MSCT can be used alone to safely rule out this diagnosis.\u003C\/p\u003E\n         \u003Cp id=\u0022p-6\u0022\u003EIn another presentation, Joanne D. Schuijf, MD, Leiden University Medical Center, the Netherlands, reported on a study in which the severity of CAD as determined by MSCT, quantitative coronary angiography (QCA), and intravascular ultrasound (IVUS), was evaluated in relation to functional assessment with myocardial perfusion imaging (MPI). Prof. Schuijf remarked that MSCT provides evidence of atherosclerosis whereas MPI is designed to detect ischemia, which explains why patients with abnormal findings on MSCT frequently have normal MPI.\u003C\/p\u003E\n         \u003Cp id=\u0022p-7\u0022\u003EProf. Schuijf reported that there was good agreement among the modalities for patients with advanced CAD (exhibiting ischemia on MPI) but that the findings were frequently discrepant for patients with mild atherosclerosis (\u003Ca id=\u0022xref-fig-2-1\u0022 class=\u0022xref-fig\u0022 href=\u0022#F2\u0022\u003EFigure 1\u003C\/a\u003E).\u003C\/p\u003E\n         \u003Cdiv id=\u0022F2\u0022 class=\u0022fig pos-float  odd\u0022\u003E\u003Cdiv class=\u0022highwire-figure\u0022\u003E\u003Cdiv class=\u0022fig-inline-img-wrapper\u0022\u003E\u003Cdiv class=\u0022fig-inline-img\u0022\u003E\u003Ca href=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/content\/spmdc\/7\/5\/19\/F2.large.jpg?width=800\u0026amp;height=600\u0026amp;carousel=1\u0022 title=\u0022MPI vs MSCT vs QCA vs IVUS.\u0022 class=\u0022fragment-images colorbox-load\u0022 rel=\u0022gallery-fragment-images-1809220223\u0022 data-figure-caption=\u0022MPI vs MSCT vs QCA vs IVUS.\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003E\u003Cimg class=\u0022fragment-image\u0022 alt=\u0022Figure 1.\u0022 src=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/content\/spmdc\/7\/5\/19\/F2.medium.gif\u0022\/\u003E\u003C\/a\u003E\u003C\/div\u003E\u003C\/div\u003E\u003Cul class=\u0022highwire-figure-links inline\u0022\u003E\u003Cli class=\u00220 first\u0022\u003E\u003Ca href=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/content\/spmdc\/7\/5\/19\/F2.large.jpg?download=true\u0022 class=\u0022highwire-figure-link highwire-figure-link-download\u0022 title=\u0022Download Figure 1.\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003EDownload figure\u003C\/a\u003E\u003C\/li\u003E\u003Cli class=\u00221\u0022\u003E\u003Ca href=\u0022http:\/\/d282kpwvnogo5m.cloudfront.net\/content\/spmdc\/7\/5\/19\/F2.large.jpg\u0022 class=\u0022highwire-figure-link highwire-figure-link-newtab\u0022 target=\u0022_blank\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003EOpen in new tab\u003C\/a\u003E\u003C\/li\u003E\u003Cli class=\u00222 last\u0022\u003E\u003Ca href=\u0022\/highwire\/powerpoint\/11217\u0022 class=\u0022highwire-figure-link highwire-figure-link-ppt\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003EDownload powerpoint\u003C\/a\u003E\u003C\/li\u003E\u003C\/ul\u003E\u003C\/div\u003E\u003Cdiv class=\u0022fig-caption\u0022 xmlns:xhtml=\u0022http:\/\/www.w3.org\/1999\/xhtml\u0022\u003E\u003Cspan class=\u0022fig-label\u0022\u003EFigure 1.\u003C\/span\u003E \n               \u003Cp id=\u0022p-8\u0022 class=\u0022first-child\u0022\u003EMPI vs MSCT vs QCA vs IVUS.\u003C\/p\u003E\n            \u003Cdiv class=\u0022sb-div caption-clear\u0022\u003E\u003C\/div\u003E\u003C\/div\u003E\u003C\/div\u003E\n         \u003Cp id=\u0022p-9\u0022\u003EFor example, some patients had no ischemia according to MPI and no significant stenosis on QCA but had evidence of atherosclerosis on MSCT and intravascular ultrasound. Prof. Schuijf concluded that the complementary nature of MPI and MSCT may allow for improved characterization of CAD. She added that more evidence is needed before it can be determined whether the combined use of the two modalities will result in improved management and outcome.\u003C\/p\u003E\n      \u003C\/div\u003E\u003Cul class=\u0022copyright-statement\u0022\u003E\u003Cli class=\u0022fn\u0022 id=\u0022copyright-statement-1\u0022\u003E\u00a9 2007 MD Conference Express\u003C\/li\u003E\u003C\/ul\u003E\u003Cspan class=\u0022highwire-journal-article-marker-end\u0022\u003E\u003C\/span\u003E\u003C\/div\u003E\u003Cspan id=\u0022related-urls\u0022\u003E\u003C\/span\u003E\u003C\/div\u003E\u003Ca href=\u0022http:\/\/mdc.sagepub.com\/content\/7\/5\/19.abstract\u0022 class=\u0022hw-link hw-link-article-abstract\u0022 data-icon-position=\u0022\u0022 data-hide-link-title=\u00220\u0022\u003EView Summary\u003C\/a\u003E\u003C\/div\u003E  \u003C\/div\u003E\n\n  \n  \u003C\/div\u003E\n\u003C\/div\u003E\n  \u003C\/div\u003E\n\u003C\/div\u003E\n\u003C\/div\u003E\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/mdc.sagepub.com\/sites\/all\/modules\/highwire\/highwire\/plugins\/highwire_markup_process\/js\/highwire_figures.js?nzm92r\u0022\u003E\u003C\/script\u003E\n\u003Cscript type=\u0022text\/javascript\u0022 src=\u0022http:\/\/mdc.sagepub.com\/sites\/all\/modules\/highwire\/highwire\/plugins\/highwire_markup_process\/js\/highwire_openurl.js?nzm92r\u0022\u003E\u003C\/script\u003E\n\u003C\/body\u003E\u003C\/html\u003E"}