RT Journal Article SR Electronic A1 Spevak, Aimee T1 SAPIEN 3 TAVR System Produces Excellent Clinical Outcomes in PARTNER II Trial JF MD Conference Express YR 2015 FD SAGE Publications VO 15 IS 5 SP 13 OP 14 DO 10.1177/1559897715583829 UL http://mdc.sagepub.com/content/15/5/13.2.abstract AB The PARTNER II trial investigated the use of the SAPIEN 3 transcatheter aortic valve replacement in patients who were high-risk/inoperable or intermediate-risk for surgical complications. Clinical outcomes were excellent, with low rates of adverse events and paravalvular leak.